CipherLab 1562 Guida Utente

Navigare online o scaricare Guida Utente per Lettori di codici a barre CipherLab 1562. CipherLab 1562 User guide Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 160
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
ScanMaster for Scanner Configuration
For 1 Series Barcode Scanners:
1070, 1500, 1502 (1D, tethered)
1560, 1562, 1660, 1661 (1D, cordless)
1504, 1704 (2D, tethered)
1564, 1664 (2D, cordless)
Version 1.30
Vedere la pagina 0
1 2 3 4 5 6 ... 159 160

Sommario

Pagina 1

ScanMaster for Scanner Configuration For 1 Series Barcode Scanners: 1070, 1500, 1502 (1D, tethered) 1560, 1562, 1660, 1661 (1D, cordless) 1504,

Pagina 2

ScanMaster User Guide 3.10.2 For 2D Scanners ...

Pagina 3 - RELEASE NOTES

88 ScanMaster User Guide 3.9 EAN-13 3.9.1 FOR 1D SCANNERS By default, the scanner is set to read EAN-13 barcodes. (= No Addon) Options of 2-digit

Pagina 4

89 Chapter 3 Changing Symbology Settings 3.9.2 FOR 2D SCANNERS By default, the scanner is set to read EAN-13 barcodes. (= No Addon) Option

Pagina 5

90 ScanMaster User Guide 3.10 GS1-128 (EAN-128) GS1-128 barcodes can be decoded only when this setting is enabled. However, for the following scanne

Pagina 6

91 Chapter 3 Changing Symbology Settings 3.10.2 FOR 2D SCANNERS Select the check box so that the scanner can read GS1-128 (also known as EAN

Pagina 7 - CONTENTS

92 ScanMaster User Guide 3.11 ISBT 128 3.11.1 FOR 1D SCANNERS By default, the scanner is set to read ISBT 128 barcodes.  No advanced settings ar

Pagina 8

93 Chapter 3 Changing Symbology Settings 3.12 MSI 3.12.1 FOR 1D SCANNERS Select the check box so that the scanner can read MSI barcodes. 

Pagina 9

94 ScanMaster User Guide 3.12.2 FOR 2D SCANNERS Select the check box so that the scanner can read MSI barcodes.  Advanced settings are provided

Pagina 10

95 Chapter 3 Changing Symbology Settings 3.13 FRENCH PHARMACODE 3.13.1 FOR 1D SCANNERS Select the check box so that the scanner can read Fre

Pagina 11

96 ScanMaster User Guide 3.14 ITALIAN PHARMACODE 3.14.1 FOR 1D SCANNERS Select the check box so that the scanner can read Italian Pharmacode barcode

Pagina 12

97 Chapter 3 Changing Symbology Settings 3.15 PLESSEY 3.15.1 FOR 1D SCANNERS Select the check box so that the scanner can read Plessey barco

Pagina 13 - INTRODUCTION

ScanMaster User Guide 4.7 Remove Special Character...

Pagina 14

98 ScanMaster User Guide 3.16 GS1 DATABAR (RSS FAMILY) It is categorized into three groups: Group I — GS1 DataBar Omnidirectional (RSS-14) This grou

Pagina 15 - USING SCANMASTER

99 Chapter 3 Changing Symbology Settings 3.16.1 FOR 1D SCANNERS Select the check box so that the scanner can read GS1 DataBar (also known as

Pagina 16

100 ScanMaster User Guide Transmit Check Digit The check digit will be included in the data being transmitted. Cancel the check box if the check dig

Pagina 17 - Introduction

101 Chapter 3 Changing Symbology Settings 3.16.2 FOR 2D SCANNERS Select the check box so that the scanner can read GS1 DataBar (also known a

Pagina 18

102 ScanMaster User Guide Convert to UPC/EAN This only applies to GS1 DataBar Omnidirectional and GS1 DataBar Limited barcodes not decoded as part o

Pagina 19

103 Chapter 3 Changing Symbology Settings 3.17 TELEPEN 3.17.1 FOR 1D SCANNERS Select the check box so that the scanner can read Telepen barc

Pagina 20 - SCANNER INFORMATION

104 ScanMaster User Guide 3.18 UPC-A 3.18.1 FOR 1D SCANNERS By default, the scanner is set to read UPC-A barcodes. (= No Addon) Options of 2-digit

Pagina 21 - FILE MENU

105 Chapter 3 Changing Symbology Settings 3.18.2 FOR 2D SCANNERS By default, the scanner is set to read UPC-A barcodes. (= No Addon) Optio

Pagina 22

106 ScanMaster User Guide 3.19 UPC-E 3.19.1 FOR 1D SCANNERS By default, the scanner is set to read UPC-E barcodes. (= No Addon) Options of 2-digit

Pagina 23 - TOOLS MENU

107 Chapter 3 Changing Symbology Settings 3.19.2 FOR 2D SCANNERS By default, the scanner is set to read UPC-E barcodes. (= No Addon) Optio

Pagina 25 - HELP MENU

108 ScanMaster User Guide 3.20 1D MORE (1504/1564/1664/1704) 3.20.1 CHINESE 25 Select the check box so that the scanner can read Chinese 25 barcode

Pagina 26

109 Chapter 3 Changing Symbology Settings 3.20.3 CODE 11 Select the check box so that the scanner can read Code 11 barcodes.  Advanced set

Pagina 27 - Chapter 1

110 ScanMaster User Guide 3.20.4 COUPON CODE Select the check box so that the scanner can read Coupon Code.  Advanced settings are provided as sho

Pagina 28 - IN THIS CHAPTER

111 Chapter 3 Changing Symbology Settings 3.20.5 COMPOSITE CODE Select the check box so that the scanner can read Composite Code.  Composi

Pagina 29 - 1.1 SCAN MODE

112 ScanMaster User Guide 3.20.6 POSTAL CODE By default, the scanner is set to read the following Postal Code:  US Postnet  US Planet  UK Post

Pagina 30

113 Chapter 3 Changing Symbology Settings 3.21 2D SYMBOLOGIES (1504/1564/1664/1704) By default, the scanner is set to read the following 2D

Pagina 31 - Changing Scanner Settings

114 ScanMaster User Guide Macro PDF Macro PDF is a special feature for concatenating multiple PDF barcodes into one file, known as Macro PDF417 or M

Pagina 32

115 You may configure in which format the collected data will be output to the host computer. Barcode read by the scanner will be processed in t

Pagina 33

116 ScanMaster User Guide 4.1 LETTER CASE By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted a

Pagina 34

117 Chapter 4 Defining Output Format 4.2 CHARACTER SUBSTITUTION “Character Substitution” replaces a character that comes up in a collected d

Pagina 35 - 1.2.5 LOW BATTERY ALARM

1 ScanMaster is a utility that makes it easier for you to configure CipherLab Barcode Scanners. It presents two ways for users to update the sca

Pagina 36

118 ScanMaster User Guide If "Keyboard Wedge", “Bluetooth HID” or “USB HID” is the interface, Key Type and Key Status will then become app

Pagina 37

119 Chapter 4 Defining Output Format 4.3 PREFIX/SUFFIX CODE Click the Prefix Code or Suffix Code field so that you can choose characters fro

Pagina 38

120 ScanMaster User Guide 4.4 CODE ID To make the Code ID configuration easier, we provide five pre-defined Code ID sets that you can make necessary

Pagina 39 - 1.9 EFFECTIVE DECODING AREA

121 Chapter 4 Defining Output Format 4.4.1 CODE ID SET 1~5 For 1504/1564/1664/1704, click the button [1D More…] or [2D Code ID…] for more sy

Pagina 40

122 ScanMaster User Guide 4.4.2 CHANGE CODE ID To modify the Code ID, click the field next to a symbology. Then, choose your Code ID from the pop-up

Pagina 41

123 Chapter 4 Defining Output Format 4.5 CODE LENGTH A two-digit code representing the length of barcode data (character count) can be inser

Pagina 42 - 1.13.1 IMAGE MODE

124 ScanMaster User Guide 4.6 OUTPUT SEQUENCE (MULTI-BARCODE EDITOR) The Multi-Barcode Editor allows you to decide the output sequence of a concaten

Pagina 43

125 Chapter 4 Defining Output Format By default, the output sequence editing of the concatenation of barcodes is not applied – “Ignored”

Pagina 44

126 ScanMaster User Guide 4.7 REMOVE SPECIAL CHARACTER You can only specify 1 character, but it will remove every matching character encountered fro

Pagina 45

127 The scanner allows advanced data editing by applying user-configured editing formats. Data is divided into fields by user-specified rules. T

Pagina 46

2 ScanMaster User Guide SYSTEM REQUIREMENTS To run the ScanMaster, one of the Windows operating systems is required:  Windows 2000  Windows XP 

Pagina 47 - 1.13.3 VIDEO MODE

128 ScanMaster User Guide 5.1 FORMAT SELECTION 5.1.1 ENABLE EDITING FORMATS If you have already configured any editing format before, you may directl

Pagina 48 - 1.14.1 WINDOWS-BASED PC

129 Chapter 5 Applying Editing Formats 5.2 CONFIGURE EDITING FORMAT Three applicable conditions can be configured to check whether the data

Pagina 49 - 1.14.2 SMART HANDHELD

130 ScanMaster User Guide Data Length The length must include prefix, suffix (0x0d by default), length code, etc. By default, barcodes with length (c

Pagina 50

131 Chapter 5 Applying Editing Formats 5.2.2 FIELD SETTINGS Number of Fields Data can be divided into at most 6 fields; each of them is num

Pagina 51 - Chapter 2

132 ScanMaster User Guide Field Setting Data eligible for editing formats is divided into fields by user-specified rules – either using the field ter

Pagina 52

133 Chapter 5 Applying Editing Formats 5.2.3 TRANSMISSION SEQUENCE After configuring the data fields and additional fields, user can now pro

Pagina 53 -  1560/1562/1564 (via 3656)

134 ScanMaster User Guide 5.2.4 EXAMPLES Example 1 — Extract data from the 10th character to the 19th character... The editing format should be confi

Pagina 54 - 2.1.2 ALTERNATE COMPOSING

135 Chapter 5 Applying Editing Formats Example 2 — Extract the date code, item number, and quantity information from barcodes. Data is enc

Pagina 55 - 2.1.3 ALPHABETS TRANSMISSION

136 ScanMaster User Guide 5.3 DATE & TIME STAMP (1664) For your better analysis of the data collected, the 1664 supports affixing date/time infor

Pagina 56 - 2.1.4 DIGITS TRANSMISSION

137 Chapter 5 Applying Editing Formats Option Description No Time Stamp Disables Date & Time Stamp. The default. Add to front of data

Pagina 57 - 2.1.6 CAPITAL LOCK STATE

3 Introduction USING SCANMASTER The ScanMaster is installed with a folder that contains two programs, ScanMaster.exe and PrintBarcode.exe. Th

Pagina 58 - 2.1.7 ALPHABETS LAYOUT

138 ScanMaster User Guide

Pagina 59 - Selecting Output Interface

139 ORIGINAL GRID CONTROL This is used for the following settings:  MAC address for Bluetooth SPP Master  Field Separator for GS1-128  Rem

Pagina 60 - 2.1.12 SNIFF MODE (VIA 3656)

140 ScanMaster User Guide SPECIAL GRID CONTROL FOR KEYBOARD INTERFACE This is used for the following settings:  Character Substitution  Prefix/Su

Pagina 61 -  1500/1502/1504/1704

141 Appendix I Grid Control For example, if you want to program "Ctrl-Shift-B", "C" for Prefix Code, the programming sequ

Pagina 62

142 ScanMaster User Guide

Pagina 63 - 2.2.9 SNIFF MODE (VIA 3656)

143 Go to Tools Menu | 2D Image Processing to start with the retrieval of signature, image or video. Refer to Tools Menu and 1.13 2D Decode S

Pagina 64 -  1500/1502

144 ScanMaster User Guide TRANSMISSION PROPERTIES RECEIVE MODE Both active and passive modes are supported. Active Mode Application on the host w

Pagina 65 - 2.3.2 MODULE TIME

145 Appendix II 2D Image Processing (1704 Only) SAVE TO FILE Auto Save Select the check box so that it will automatically save to file upo

Pagina 66 - 2.4 BLUETOOTH HID

146 ScanMaster User Guide START 2D IMAGE PROCESSING RETRIEVING AN IMAGE 1) Click to start with image processing in Image Mode. 2) Depending on

Pagina 67

147 Appendix II 2D Image Processing (1704 Only) RETRIEVING A VIDEO 1) Click to start with image processing in Video Mode. 2) Dependin

Pagina 68 - 2.4.5 INTER-FUNCTION DELAY

4 ScanMaster User Guide HOW TO CONFIGURE THE SCANNER? 1) Run ScanMaster.exe on your PC. 2) From the drop-down box of [Select Scanner] on the toolb

Pagina 69 - 2.4.6 AUTHENTICATION

148 ScanMaster User Guide RETRIEVING A SIGNATURE 1) Click to start with image processing in Decode Mode. 2) Depending on the Receive Mode: Act

Pagina 70 - 2.4.8 SNIFF MODE

5 Introduction 3. The scanner checks one by one whether the read barcode meets the criteria for a concatenation of barcodes as configured on

Pagina 71 - 2.5 BLUETOOTH SPP SLAVE MODE

6 ScanMaster User Guide SETUP BARCODES To recover the default settings, the scanner needs to read these barcodes one by one. Setup Barcodes Indicat

Pagina 72 - 2.5.1 AUTHENTICATION

7 Introduction  You can always restore the default settings.  The setup barcodes are categorized into groups of related settings, such as

Pagina 73 - 2.5.5 ACK/NAK TIMEOUT

Copyright © 2008~2011 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided un

Pagina 74

8 ScanMaster User Guide SCANNER INFORMATION After a scanner model is selected, a drop-down tree will be presented in the ScanMaster window. It enabl

Pagina 75 -  “MAC Address” barcode

9 Introduction MENU BAR The menu bar contains a number of menus that cause the program to take actions. Each menu contains a list of commands.

Pagina 76 - 2.7 USB HID VIA 3656/3610

10 ScanMaster User Guide CONFIGURE MENU The Configure Menu contains one command that displays the [Scanner Settings] dialog box that accesses the s

Pagina 77

11 Introduction TOOLS MENU The Tools Menu contains the submenus that launch the actions as tabulated below: Command Action Read Scanner Setti

Pagina 78

12 ScanMaster User Guide 2D Image Processing Refer to 1.13 2D Decode Settings (1704) and Appendix I — 2D Image Processing (1704 Only). Download Sc

Pagina 79

13 Introduction  The [COM Port Properties] dialog box provides the access to set the COM port properties on your PC. For Bluetooth SPP or U

Pagina 80

14 ScanMaster User Guide Command Action About ScanMaster Provides the information about the version, copyright and developer of the ScanMaster. TOO

Pagina 81

15 The [Scanner Settings] dialog box features a number of tabbed property pages which enable your configuration to the barcode scanner that opti

Pagina 82 -  1504

16 ScanMaster User Guide IN THIS CHAPTER 1.1 Scan Mode ... 17 1.2 Power Management (156

Pagina 83 - Chapter 3

17 Chapter 1 Changing Scanner Settings 1.1 SCAN MODE A variety of scan modes are supported – select the scan mode that best suits the requir

Pagina 84

Version Date Notes 1.30 Dec. 08, 2011  New model 1664 included. Changes applied throughout the manual. Critical updates are: o “RTC Time Setup

Pagina 85 - 3.1.1 FOR 1D SCANNERS

18 ScanMaster User Guide Continuous Mode The scanner is always scanning.  To decode the same barcode repeatedly, shift the scan beam away and targ

Pagina 86

19 Chapter 1 Changing Scanner Settings Multi-Barcode Mode The scanner will be scanning as long as the trigger is held down, capable of decod

Pagina 87

20 ScanMaster User Guide 1.1.4 RE-READ DELAY This is also referred to as the “Blocking Time”, which is used to prevent the scanner from accidentally

Pagina 88 - 3.2.2 FOR 2D SCANNERS

21 Chapter 1 Changing Scanner Settings 1.2 POWER MANAGEMENT (1560/1562/1564/1660/1661/1664) The Bluetooth-enabled models such as 1560, 1562,

Pagina 89

22 ScanMaster User Guide After establishing a WPAN connection successfully… 1. Once a WPAN connection is established successfully, the scanner stay

Pagina 90

23 Chapter 1 Changing Scanner Settings 1.2.3 AUTO POWER OFF The setup of an “Auto Power Off” time is available to any scan mode other than C

Pagina 91

24 ScanMaster User Guide 1.3 STATUS INDICATOR For 1704, refer to 1.12 More Settings for Good Read Vibrator. 1.3.1 BEEPER VOLUME Beeping functions

Pagina 92 - 3.4.2 FOR 2D SCANNERS

25 Chapter 1 Changing Scanner Settings 1.7 AUTO SENSE (1500/1560/1564) This mode is only applicable when you want to seat the 1500/1560/1564

Pagina 93 - 3.5.1 FOR 1D SCANNERS

26 ScanMaster User Guide 1.8 MEMORY MODE (1560/1562/1564/1660/1661/1664) Memory mode is disabled by default. When the scanner is in memory mode, it

Pagina 94 - 3.5.2 FOR 2D SCANNERS

27 Chapter 1 Changing Scanner Settings 1.9 EFFECTIVE DECODING AREA In default state, the effective decoding area is 100% covered by the scan

Pagina 95

1.17 Jan. 10, 2011  New: add 1070  Modified: Introduction — 1661 supports Settings Type in Tools Menu | Read or Download scanner settings  M

Pagina 96

28 ScanMaster User Guide 1.10 TRANSMIT BUFFER (1560/1562/1564/1660/1661/1664) By default, transmit buffer is enabled and ready for use when the scan

Pagina 97

29 Chapter 1 Changing Scanner Settings 1.11 PICKLIST MODE (1504/1564/1664/1704) Picklist Mode is deselected by default. Select it to enable

Pagina 98

30 ScanMaster User Guide 1.13.1 IMAGE MODE Note: When selecting Image Mode, you can ignore the Decoding Illumination/Auto-exposure settings in [Pr

Pagina 99

31 Chapter 1 Changing Scanner Settings This is used to control the illumination banks on the scan engine. Options are –  Full: Enables t

Pagina 100 - ScanMaster User Guide

32 ScanMaster User Guide Timeout Set the amount of time the decoder remains in Image Mode. The decoder exits Image Mode upon a trigger event, or whe

Pagina 101 - Changing Symbology Settings

33 Chapter 1 Changing Scanner Settings Note: When selecting Decode Mode, the Image Capture Illumination/Auto-exposure settings in [Preferen

Pagina 102

34 ScanMaster User Guide  Auto: Switches the illumination from left to right bank.  Left: Enables the left bank, which is on the left when facin

Pagina 103 - 3.10.2 FOR 2D SCANNERS

35 Chapter 1 Changing Scanner Settings 1.13.3 VIDEO MODE Target Video Frame Size Select the number of 100-byte blocks to transmit per secon

Pagina 104

36 ScanMaster User Guide 1.14 PAGER BEEP (1664) This function helps track down the 1664 scanner should it be misplaced or fall out of sight. The Pag

Pagina 105

37 Chapter 1 Changing Scanner Settings 2) It is the defined time for Power-Saving again. (The scanner returns to power-saving.) 1.14.2 SMAR

Pagina 106 - 3.12.2 FOR 2D SCANNERS

1.13 Feb. 04, 2010  Modified: 1.2 Power Management (1560/1562/1660) — add Bluetooth SPP Master Mode for 1660  Modified: 2.4.1 Keyboard Type — ad

Pagina 107 - 3.13.2 FOR 2D SCANNERS

38 ScanMaster User Guide

Pagina 108 - 3.14 ITALIAN PHARMACODE

39 In order to establish a proper wired connection between your computer and the scanner, we suggest that you follow these instructions – 1)

Pagina 109 - 3.15.2 FOR 2D SCANNERS

40 ScanMaster User Guide  For 1660/1661/1664 scanners, install batteries, and press & hold the [Power/Delete] key to turn it on. IN THIS CHAPT

Pagina 110

41 Chapter 2 Selecting Output Interface 2.1 KEYBOARD WEDGE This interface is for the following scanners:  1070/1500/1502/1504/1704  1560

Pagina 111

42 ScanMaster User Guide 2.1.1 KEYBOARD TYPE By default, the keyboard type is set to PCAT (US). The following keyboard types are supported – No. K

Pagina 112

43 Chapter 2 Selecting Output Interface 2.1.3 ALPHABETS TRANSMISSION By default, the alphabets transmission is case-sensitive, which means t

Pagina 113

44 ScanMaster User Guide 2.1.4 DIGITS TRANSMISSION By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if y

Pagina 114

45 Chapter 2 Selecting Output Interface 2.1.5 CAPITAL LOCK TYPE Cap Lock Type Description Normal Normal type Capital Lock When enabled,

Pagina 115 - 3.17.2 FOR 2D SCANNERS

46 ScanMaster User Guide 2.1.7 ALPHABETS LAYOUT By default, the alphabets layout is set to normal mode, also known as the standard English layout. S

Pagina 116

47 Chapter 2 Selecting Output Interface Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). Th

Pagina 117

 Modified: section 2.1.11 Inter-Function Delay — allows 0~254  Modified: section 2.2 RS-232 — screenshot updated  Modified: section 2.2.6 Int

Pagina 118

48 ScanMaster User Guide 2.1.12 SNIFF MODE (VIA 3656) By default, this power-saving feature is enabled for 1560/1562/1564, meaning the scanner will

Pagina 119

49 Chapter 2 Selecting Output Interface 2.2 RS-232 This interface is for the following scanners:  1500/1502/1504/1704  1560/1562/1564 (v

Pagina 120 - 3.20.2 TRIOPTIC CODE 39

50 ScanMaster User Guide 2.2.1 BAUD RATE By default, it is set 9600 bps for 1500/1502, but 115200bps for 1504/1704 and 3656. Select other value that

Pagina 121 - 3.20.3 CODE 11

51 Chapter 2 Selecting Output Interface 2.2.8 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK

Pagina 122

52 ScanMaster User Guide 2.3 WAND EMULATION This interface is for the following scanners:  1500/1502 Connect the scanner to a portable data termi

Pagina 123

53 Chapter 2 Selecting Output Interface 2.3.1 MARGIN TIME By default, it is set 20 milliseconds as the time span for the change in state for

Pagina 124

54 ScanMaster User Guide 2.4 BLUETOOTH HID This interface is provided for the following scanners:  1560/1562/1564 (connecting to dongle or via 365

Pagina 125

55 Chapter 2 Selecting Output Interface 2.4.1 KEYBOARD TYPE By default, the keyboard type is set to PCAT (US). The following keyboard types

Pagina 126

56 ScanMaster User Guide 2.4.3 CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch. You may change it to process data

Pagina 127 - Chapter 4

57 Chapter 2 Selecting Output Interface 2.4.6 AUTHENTICATION When any changes are made to authentication and PIN code on the scanner side,

Pagina 128 - 4.1 LETTER CASE

CONTENTS RELEASE NOTES ...

Pagina 129 - 4.2 CHARACTER SUBSTITUTION

58 ScanMaster User Guide Note: When using Bluetooth HID, some device driver may not support pre-defined PIN code for authentication. In this case, m

Pagina 130

59 Chapter 2 Selecting Output Interface 2.5 BLUETOOTH SPP SLAVE MODE This interface is provided for the following scanners:  1560/1562/156

Pagina 131 - Defining Output Format

60 ScanMaster User Guide 2.5.1 AUTHENTICATION When any changes are made to the authentication and PIN code on the scanner side, you have to remove t

Pagina 132 - 4.4 CODE ID

61 Chapter 2 Selecting Output Interface 2.5.2 DEVICE NAME BROADCASTING Device Name Broadcasting is selected by default. Deselect it to hide

Pagina 133 - 4.4.1 CODE ID SET 1~5

62 ScanMaster User Guide 2.6 BLUETOOTH SPP MASTER MODE This interface is provided for the following scanners:  1560/1562/1564 (connecting to dongl

Pagina 134

63 Chapter 2 Selecting Output Interface Note: In SPP Master Mode, if it fails to re-connect within the specified period of time (2 minutes

Pagina 135 - 4.5 CODE LENGTH

64 ScanMaster User Guide 2.7 USB HID VIA 3656/3610 This interface is provided for the following scanners:  1560/1562/1564 (via 3656)  1660/1661/

Pagina 136 -  Code Type

65 Chapter 2 Selecting Output Interface 2.8 USB VIRTUAL COM VIA 3656/3610 This interface is provided for the following scanners:  1560/156

Pagina 137

66 ScanMaster User Guide 2.9 DIRECT USB HID This interface is provided for the following scanners:  1070  1504  1661  1664  1704 For the

Pagina 138 - 4.7 REMOVE SPECIAL CHARACTER

67 Chapter 2 Selecting Output Interface 2.9.1 CABLE AUTO-DETEC FOR 1504/1704 For 1504/1704, the scanner will detect the interface automatica

Pagina 139 - Chapter 5

ScanMaster User Guide 1.13 2D Decode Settings (1704) ...

Pagina 140 - 5.1.2 EXCLUSIVE DATA EDITING

68 ScanMaster User Guide 2.10 DIRECT USB VCOM This interface is for the following scanners:  1070  1504  1661  1664  1704 For the connec

Pagina 141 - 5.2.1 APPLICABLE CONDITIONS

69 Chapter 2 Selecting Output Interface 2.10.1 CABLE AUTO-DETEC FOR 1504/1704 For 1504/1704, the scanner will detect the interface automatic

Pagina 142

70 ScanMaster User Guide 2.11 DIRECT USB VCOM_CDC This interface is for the following scanners:  1070  1504 Use the provided USB cable to conne

Pagina 143 - 5.2.2 FIELD SETTINGS

71 Barcode symbologies are application-dependent. You may enable or disable any of them, and configure their parameters according to the require

Pagina 144

72 ScanMaster User Guide IN THIS CHAPTER 3.1 Codabar... 73 3.2 Code 25 — Industrial

Pagina 145 - 5.2.3 TRANSMISSION SEQUENCE

73 Chapter 3 Changing Symbology Settings 3.1 CODABAR 3.1.1 FOR 1D SCANNERS By default, the scanner is set to read Codabar barcodes.  Adv

Pagina 146 - 5.2.4 EXAMPLES

74 ScanMaster User Guide 3.1.2 FOR 2D SCANNERS By default, the scanner is set to read Codabar barcodes.  Advanced settings are provided as shown

Pagina 147 - Applying Editing Formats

75 Chapter 3 Changing Symbology Settings 3.2 CODE 25 — INDUSTRIAL 25 3.2.1 FOR 1D SCANNERS By default, the scanner is set to read Industrial

Pagina 148 - OPTIONS

76 ScanMaster User Guide 3.2.2 FOR 2D SCANNERS By default, the scanner is set to read Industrial 25 barcodes.  Advanced settings are provided as

Pagina 149 - MORE BUTTON

77 Chapter 3 Changing Symbology Settings 3.3 CODE 25 — INTERLEAVED 25 3.3.1 FOR 1D SCANNERS By default, the scanner is set to read Interleav

Pagina 150

ScanMaster User Guide 2.5.2 Device Name Broadcasting ...61

Pagina 151 - Appendix I

78 ScanMaster User Guide 3.3.2 FOR 2D SCANNERS By default, the scanner is set to read Interleaved 25 barcodes.  Advanced settings are provided a

Pagina 152

79 Chapter 3 Changing Symbology Settings 3.4 CODE 25 — MATRIX 25 3.4.1 FOR 1D SCANNERS Select the check box so that the scanner can read Mat

Pagina 153 - GRID CONTROL — SCAN CODE

80 ScanMaster User Guide 3.4.2 FOR 2D SCANNERS Select the check box so that the scanner can read Matrix 25 barcodes.  Advanced settings are prov

Pagina 154

81 Chapter 3 Changing Symbology Settings 3.5 CODE 39 3.5.1 FOR 1D SCANNERS By default, the scanner is set to read Code 39 barcodes.  Adv

Pagina 155 - Appendix II

82 ScanMaster User Guide 3.5.2 FOR 2D SCANNERS By default, the scanner is set to read Code 39 barcodes.  Advanced settings are provided as shown

Pagina 156 - COM PORT SETTING

83 Chapter 3 Changing Symbology Settings Length Qualification To prevent the "short scan" error, define the "Length Qualifica

Pagina 157 - AUTO FILE NAME

84 ScanMaster User Guide 3.6 CODE 93 3.6.1 FOR 1D SCANNERS By default, the scanner is set to read Code 93 barcodes.  No advanced settings are av

Pagina 158 - RETRIEVING AN IMAGE

85 Chapter 3 Changing Symbology Settings 3.7 CODE 128 3.7.1 FOR 1D SCANNERS By default, the scanner is set to read Code 128 barcodes.  N

Pagina 159 - RETRIEVING A VIDEO

86 ScanMaster User Guide 3.8 EAN-8 3.8.1 FOR 1D SCANNERS By default, the scanner is set to read EAN-8 barcodes. (= No Addon) Options of 2-digit an

Pagina 160 - RETRIEVING A SIGNATURE

87 Chapter 3 Changing Symbology Settings 3.8.2 FOR 2D SCANNERS By default, the scanner is set to read EAN-8 barcodes. (= No Addon) Options

Commenti su questo manuale

Nessun commento