2.4.3 CHARACTER TRANSMIT MODE
By default, HID interface sends data to the host in batch. You may change it to process
data one character at a time.
2.4.4 INTER-CHARACTER DELAY
By default, the inter-character delay is set to zero. Enter a value, ranging from 0 to 254
in units of millisecond, to match the computer response time of the keyboard interface.
Such delay time is inserted between every character being transmitted. The longer the
delay time is, the slower the transmission speed will be.
2.4.5 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Enter a value, ranging from 0 to 254 in
units of millisecond, to match the computer response time of the RS-232 interface. Such
delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The
longer the delay time is, the slower the transmission speed will be.