48
ScanMaster User Guide
3.12 MSI
Select the check box so that the scanner can read MSI barcodes.
Advanced settings are provided as shown below.
Checksum Verification
Select the checksum calculation used to verify MSI barcodes. If the checksum is incorrect, the
barcode will not be accepted.
Checksum Transmission
Select the way the check digits will be included in the data being transmitted.
Length Qualification
Because of the weak structure of MSI barcodes, it is possible to make a "short scan" error. To
prevent the "short scan" error, configure the "Length Qualification" settings to ensure that the
correct barcode is read by qualifying the allowable code length. The barcode can be qualified by
"Fixed Length" or "Max/Min Length".
For "Fixed Length", up to 2 fixed lengths can be specified.
For "Max/Min Length", the maximum length and the minimum length must be specified. The
scanner will only accept MSI barcodes with lengths that fall between max/min lengths
specified.